Issue 02/2015 Art. No. 7001-0081
Operating Manual
APT.line™ BF
Incubators with forced convection
with microprocessor temperature controller
Model
Art. No.
BF 53
9010-0235, 9110-0235
BF 53-UL
9010-0236, 9110-0236
BF 115
9010-0237, 9110-0237
BF 115-UL
9010-0238, 9110-0238
BF 240
9010-0239, 9110-0239
BF 240-UL
9010-0240, 9110-0240
BF 400
9010-0241, 9110-0241
BF 400-UL
9010-0242, 9110-0242
BF 720
9010-0243, 9110-0243
BF 720-UL
9010-0244, 9110-0244
BINDER GmbH
Address Post office box 102
D-78502 Tuttlingen
Tel. +49 7462 2005 0
Fax +49 7462 2005 100
Internet http://www.binder-world.com
E-mail info@binder-world.com
Service Hotline +49 7462 2005 555
Service Fax +49 7462 2005 93 555
Service E-Mail service@binder-world.com
Service Hotline USA +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS +7 495 988 15 16
Page view 0
1 2 3 4 5 6 ... 50 51

Summary of Contents

Page 1 - Operating Manual

Issue 02/2015 Art. No. 7001-0081 Operating Manual APT.line™ BF Incubators with forced convection with microprocessor temperature controller

Page 2 - EG – KONFORMITÄTSERKLÄRUNG

BF (E1) 02/2015 page 10/51 1.4 Type plate The type plate is located on the unit front behind the door, bottom left-hand. Figure 1: Type plate (e

Page 3

BF (E1) 02/2015 page 11/51 Symbol on the type plate Information CE conformity marking Electrical and electronic equipment manufactured / placed o

Page 4 - Product registration

BF (E1) 02/2015 page 12/51 The incubator with forced convection BF does not dispose of any measures of explosion protection. DANGER Explosion haz

Page 5 - Content

BF (E1) 02/2015 page 13/51 Following the instructions in this operating manual and conducting regular maintenance work (chap. 9) are part of the i

Page 6

BF (E1) 02/2015 page 14/51 2.1 Equipment overview BF (1) Display (2) Set-point value key (3) Selector keys (4) Time management key (5) Swi

Page 7 - 1. Safety

BF (E1) 02/2015 page 15/51 CAUTION Sliding or tilting the unit. Damage to the unit. Risk of injury by lifting heavy loads. ∅ Do NOT lift or t

Page 8

BF (E1) 02/2015 page 16/51 • Permissible ambient temperature range during transport: -10 °C up to +60 °C / 14 °F up to 140 °F. You can order trans

Page 9 - • UL units: outer unit door

BF (E1) 02/2015 page 17/51 DANGER Explosion hazard. Danger of death. ∅ Do NOT operate the unit in potentially explosive areas.  KEEP explosive

Page 10 - 1.4 Type plate

BF (E1) 02/2015 page 18/51 4.2 Connection to a suction plant (optional) When directly connecting a suction plant the spatial temperature exactitud

Page 11 - CAUTION

BF (E1) 02/2015 page 19/51 5.3 Air change Opening the air flap in the exhaust duct serves to adjust the air change. Without connecting a suction

Page 12

BF (E1) 02/2015 page 2/51 EC – declaration of conformity EG – KONFORMITÄTSERKLÄRUNG EC - DECLARATION OF CONFORMITY CE - DECLARATION DE CONFORMI

Page 13 - 2. Unit description

BF (E1) 02/2015 page 20/51 5. Press button to return to normal display (actual value display) (automatically after approx. 30 seconds). Adjust t

Page 14 - 2.1 Equipment overview BF

BF (E1) 02/2015 page 21/51 6. Press button to return to normal display / actual value display (automatically after approx. 30 seconds). Adjust t

Page 15

BF (E1) 02/2015 page 22/51 6.3.1 Switching between Continuous operation and Timer operation Press the time management button . The controller di

Page 16

BF (E1) 02/2015 page 23/51 6.3.3 Setting the timer values 1. Press the time management button . The controller indicates its current time funct

Page 17

BF (E1) 02/2015 page 24/51 6.4 User level settings By pressing down button in normal display (actual value display) for 5 sec, you enter the use

Page 18 - 5. Start up

BF (E1) 02/2015 page 25/51 6.4.1 Temperature unit change between degrees Celsius °C and degrees Fahrenheit °F If required, the temperature display

Page 19 - 6. Controller setting

BF (E1) 02/2015 page 26/51 1. Press down button for approx. 5 seconds. The display alternately shows “unit” and the temperature unit:

Page 20 -

BF (E1) 02/2015 page 27/51 4. Set the required address with buttons . You can enter address values between 1 and 30. 5. The set value is automa

Page 21

BF (E1) 02/2015 page 28/51 6.4.5 Setting the interface mode and, if appropriate, the printer interval 1. Press down button for approx. 5 second

Page 22 - 6.3.2 Continuous operation

BF (E1) 02/2015 page 29/51 The printer intervals via the RS 422 interface can be set between 1 and 255 min. Setting “0” signifies the printer inter

Page 23

BF (E1) 02/2015 page 3/51 Die oben beschriebenen Produkte sind konform mit folgenden harmonisierten Normen: The products described above are in con

Page 24 - 6.4 User level settings

BF (E1) 02/2015 page 30/51 7. Temperature safety device class 3.1 (DIN 12880) The temperature safety device class 3.1 serves to protect the incuba

Page 25

BF (E1) 02/2015 page 31/51 Function check: Check the temperature safety device class 3.1 at appropriate intervals for its functionality. It is re

Page 26 - 6.4.3 Chamber addressing

BF (E1) 02/2015 page 32/51 8.3 Data logger kits (option) BINDER Data Logger Kits offer an independent long-term measuring system for temperature.

Page 27

BF (E1) 02/2015 page 33/51 8.6 Water protected internal socket (option) You can turn on or off the disconnectable water protected internal socket

Page 28

BF (E1) 02/2015 page 34/51 9. Maintenance, cleaning, and service 9.1 Maintenance intervals, service DANGER Electrical hazard. Danger of death.

Page 29 - 6.6 General notes

BF (E1) 02/2015 page 35/51 9.2.1 Cleaning Disconnect the chamber from the power supply before cleaning. Disconnect the power plug. The interior o

Page 30

BF (E1) 02/2015 page 36/51 Recommended precautions: To protect the eyes use sealed protective goggles. Suitable protective gloves with full contact

Page 31 - 8. Options

BF (E1) 02/2015 page 37/51 Recommended precautions: To protect the eyes use sealed protective goggles. CAUTION Eye contact. Eye damage due to c

Page 32 - 2 3

BF (E1) 02/2015 page 38/51 10. Disposal 10.1 Disposal of the transport packing Packing element Material Disposal Straps to fix packing on pallet

Page 33 - WARNING

BF (E1) 02/2015 page 39/51 CAUTION Violation against existing law. ∅ Do NOT dispose of BINDER devices at public collecting points.  Have the d

Page 34

BF (E1) 02/2015 page 4/51 Product registration

Page 35 - PRECAUTION

BF (E1) 02/2015 page 40/51 CAUTION Violation against existing law. ∅ Do NOT dispose of BINDER devices at public collecting points.  Have the d

Page 36

BF (E1) 02/2015 page 41/51 11. Troubleshooting Fault description Possible cause Required measures Temperature Set-point temperature is not reached

Page 37

BF (E1) 02/2015 page 42/51 12. Technical description 12.1 Factory calibration and adjustment This unit was calibrated and adjusted in the facto

Page 38 - 10. Disposal

BF (E1) 02/2015 page 43/51 12.4 BF technical data Unit size 53 115 240 400 720 Exterior dimensions Width mm / inch 634 24.96 834 32.83 1034 40.71

Page 39

BF (E1) 02/2015 page 44/51 Unit size 53 115 240 400 720 Electrical data IP system of protection acc. to EN 60529 20 20 20 20 20 Nominal voltage (±1

Page 40

BF (E1) 02/2015 page 45/51 Options / accessories Access ports with various diameters, with silicone plug Rack, chrome-plated or stainless steel Per

Page 41 - 11. Troubleshooting

BF (E1) 02/2015 page 46/51 13. Contamination clearance certificate Unbedenklichkeitsbescheinigung 13.1 For units located outside North America an

Page 42 - 12. Technical description

BF (E1) 02/2015 page 47/51 3.3 Measures to be taken in case of skin contact or release into the atmosphere / Maßnahmen bei Personenkontakt oder Fr

Page 43 - 12.4 BF technical data

BF (E1) 02/2015 page 48/51 We herewith declare that the following measures have been taken / Wir erklären, dass folgende Maßnahmen getroffen wurden

Page 44 - 12.5 Equipment and Options

BF (E1) 02/2015 page 49/51 13.2 For units in North America and Central America Product Return Authorization Request Please complete this form an

Page 45

BF (E1) 02/2015 page 5/51 Content EC – declaration of conformity ...

Page 46

BF (E1) 02/2015 page 50/51 Customer (End User) Decontamination Declaration Health and Hazard Safety declaration To protect the health of our emplo

Page 47

BF (E1) 02/2015 page 51/51 4. Declaration of Decontamination For toxic, radioactive, biologically and chemically harmful or hazardous substances,

Page 48

BF (E1) 02/2015 page 6/51 8.4 Analog output for temperature (option) ...

Page 49

BF (E1) 02/2015 page 7/51 Dear customer, For the correct operation of the incubators with forced convection BF, it is important that you read this

Page 50

BF (E1) 02/2015 page 8/51 WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious (irreversibl

Page 51

BF (E1) 02/2015 page 9/51 Prohibition signs Do NOT touch Do NOT spray with water Information to be observed in order to ensure optimum funct

Related models: BF 115 | BF 240 | BF 400 | BF 720 |

Comments to this Manuals